Collapsable Products List |
---|
Show List | Hide List |
- Case Studies (PDF)
- NYSERDA Long Term Testing of Intellidyne Validates Results
- Brookhaven National Labs Test
- Combo Savings Summary
- Fuel Reduction Pilot Program (Erial Elementry School, Erial, New Jersey)
- Fuel Reduction Pilot Program (Fort Dix Military Base, Ft. Dix, New Jersey)
- Fuel Reduction Pilot Program (Inc. Village of Freeport Electric Generating Plant, Freeport, New York)
- Fuel & Electricity Reduction Pilot Program (Starwood's Sheraton Hotel, Stamford, Connecticut)
Product Case Studies
-
NYSERDA Long Term Testing of Intellidyne Validates Results
Intellidyne LLC and Brookhaven National Laboratories, Dr. Thomas Butcher
The patented IntelliCon control concept, invented and manufactured by Intellidyne LLC, is a retrofit product developed to reduce the energy consumption of oil and gas-fired boilers, and refrigeration and air conditioning equipment. The control uses measurements of system temperatures to estimate overall heating or cooling load and in response varies the operating “deadband” of the primary control with resultant reductions of energy consumption and cycling.
For boiler applications the control can have an added benefit in reducing air pollutant emissions. During startup and shutdown there are elevated levels of emissions associated with incomplete combustion including smoke, CO, and hydrocarbons. Reducing burner cycling rates will reduce the total amount of these emissions.
Read more: (PDF)
-
Brookhaven National Labs Test
Brookhaven Science Associates, Departement of Applied Science
These results show that the IntelliCon control has a significant positive effect on the operation of the boiler. For oil-fired boilers such as the one tested, the 64.4% reduction in cycling rate should also result in a substantial reduction in cumulative soot emissions as well as ‘wear and tear’ on the boiler, due to the reduced number of burner starts.
Read more: (PDF)
-
Combo Savings Summary
Intellidyne LLC Datasheet
Savings by System Size and Type
Read more: (PDF)
-
Fuel Reduction Pilot Program
Erial Elementry School, Erial, New Jersey, for Allied Energy Systems
Test Results For A Hot-Water Boiler
Read more: (PDF)
-
Fuel Reduction Pilot Program
Fort Dix Military Base, Ft. Dix, New Jersey
Test Results For Hydronic And Steam Heating/Hot Water Boilers
Read more: (PDF)
-
Fuel Reduction Pilot Program
Inc. Village of Freeport Electric Generating Plant, Freeport, New York
Test Results For Steam Heating Boiler
Read more: (PDF)
-
Fuel & Electricity Reduction Pilot Program
Starwood's Sheraton Hotel, Stamford, Connecticut
Test Results For Domestic Hot-Water Heater And Commercial Refrigeration