The Intellidyne product line is an outstanding way to improve the efficiencies of existing boilers and HVAC equipment without expensive retrofits or replacements.

In 2001, we begin evaluating the Intellidyne line, and after extensive field research and positive customer testimony, Smart Building Products chose Intellidyne Controls as our premier commercial HVAC control line because of ease of installation, commissioning and trouble-free operation.

Our Flagship Product:

Intellidyne HVAC Controls

Intellidyne HVAC and Boiler Optimization Controls

Introduction

IntelliCon®-CHW is a microprocessor-controlled fuel-saving device for commercial hot-water heating systems.

IntelliCon®-CHSis a microprocessor-controlled fuel-saving device for commercial steam heating systems.

The Intellidyne controller reduces: fuel consumption, wear on parts, flue emissions, and electrical usage, when installed on any new or existing gas or oil burner.

A heating system must be able to provide acceptable comfort at the lowest anticipated outdoor temperature. In the U.S. and abroad, most commercial boilers have a heating capacity between 1.5 to 2 times larger than that needed to maintain the facility’s temperature on those extreme days. Due to this over-sizing of the boiler, the burner will cycle on and off continuously. Even on boilers with proportional controls, once the heating load goes below the burner’s low-fire point, the burner will cycle on and off to prevent overheating of the system water.

Intellidyne Features

  • 5 Year full replacement warranty
  • Automatic restart on power failure
  • Surge protection incorporated into circuitry
  • Fully compatible with all energy management systems
  • UL Listed
  • NYSERDA Tested
  • Maintenance Free

Intellidyne Boiler Controller Benefits

  • 10% guaranteed savings in fuel usage
  • Reduced fuel consumption
  • Reduced emissions
  • Reduced burner ignitions
  • Reduced burner electric usage
  • Improved air quality
  • Low installation cost
  • Excellent return on investment

IntelliCon®-CHW saves energy by adjusting the burner run pattern to match the system’s “heat load.” Its action is similar to the industry-accepted method of “outdoor-air temperature reset control,” but does not require an outdoor air temperature sensor or the need to profile the building in order to adjust the reset” controller properly.

IntelliCon-CHW determines the “heat load” by using an easily installed strap-on temperature sensor that monitors the boiler’s out-flow water temperature and the rate that this temperature is changing. Using our patented technology, IntelliCon-CHW increases “system efficiency” thus the heating system uses less fuel to generate the same amount of heat. This is done by dynamically changing the aquastat’s effective dead-band based upon the measured “heating load.” This causes the average water temperature to be varied (depending upon the measured load), and is accomplished by extending the burner’s “off-time.”

Extending the “off-time” also results in longer burns that are more efficient and a reduction in burner on/off cycling. Just as computer control has increased the gas mileage of automobiles: IntelliCon-CHW improves the fuel utilization of heating systems, by supplementing the antiquated on/off control action of the aquastat with the analysis and control capabilities of a computer.

Facility engineers will appreciate the illuminated LCD readout, which displays useful information relative to the unit’s status, system temperatures, and burner run-time, all of which are useful for system maintenance. IntelliCon-CHW typically reduces fuel consumption 10% to 20% and decreases burner cycling 30% or more.

Installation, by a qualified service technician, takes about 60 - 90 minutes and does not require any programming or adjustments. The IntelliCon-CHW small 7 1/2”H x 9 1/2”W x 4”D size allows it to be installed almost anywhere. After installation, IntelliCon-CHW does not require any maintenance.


Types of Facilities Recommended For Intellidyne

Buildings with boiler plants that are hot water or steam and are used primarily for heating and domestic hot water production.  Small modular boiler plants are generally not a good fit for the Intellidyne Boiler Controller.  Based upon prior experience, process heating loads should be approached with caution due to its constant load nature.

Energy Savings Methodology and Results

The savings approach is based upon reducing the amount of boiler on time without reducing the heating response time or system capacity in response to warmer periods of the year, and when demand for heating is low or non existent. Energy savings methodology is primarily based upon the reduced quantity of pre-purge and post-purge air that is part of the normal firing cycle.  The second contributor to savings is due to the higher overall temperature differential between the water side and the fire side of the boiler system as well as the longer combustion cycle.